Commands - 16
CLEAR COUNT
Tasking Statement
SYNTAX: CLEAR COUNT n [,n1] . . . [,nm]
PURPOSE: To clear the accumulated count in a software event counter.
REMARKS: CLEAR COUNT is functional both during timed operation and when the counter is stopped. The
counter number n ranges from 0 to 7.
See the Multitasking Chapter for more information.
NOTE: This statement has no effect on 82C54 hardware counters.
RELATED: CONFIG COUNT, ON COUNT, RESUME COUNT, START COUNT, STOP COUNT
EXAMPLE: 10 CLEAR COUNT 0
10 CLEAR COUNT 5,6,3
ERROR: <Data negative> – for n